Applications
The YSL-400KN-500 is designed for industrial applications requiring high thrust, speed and positioning accuracy, including heavy-machinery assembly, metallurgical handling and pressing, automated production lines and heavy-equipment commissioning.
Customization
Customized electric cylinders from 10 to 150 tonnes are available with application-specific mounting and mechanical configurations.
Core Specifications
- Mounting: Mounting can be adapted to customer installation and operating conditions; confirm the arrangement and dimensions in the approved project drawing
- Rated axial thrust: 400 kN
- Instantaneous overload: 1,000 kN
- Static load capacity: 1,229 kN
- Effective stroke: 500 mm
- Rated speed: 150 mm/s
- Screw lead: 20 mm
- Reduction ratio: 3.24
- Servo-motor power: 79 kW
- Rated motor speed: 1,500 r/min
Structure and Advantages
- Servo motor and mechanical transmission for accurate, stable operation
- Internal anti-rotation mechanism
- Proximity-switch stroke limits
- Optional motor brake
- Robust, standardized design for safe high-load operation
Technical Notes
- Rated force acts axially; avoid side loading.
- Stroke limits depend on correctly installed proximity switches.
- Installation must follow the approved product drawing.
Before requesting a quotation
Describe the axial working force, short-duration loads, stroke, velocity profile and cycle timing. Mounting can be adapted to the customer’s installation and operating conditions. Provide the installation drawing and confirm the final interfaces and dimensions. The listed overload and static-load figures are separate from the working thrust and require defined duration and operating conditions.
Related products and project examples
Frequently asked questions
Can the mounting arrangement be customized?
Yes. The mounting arrangement can be adapted to the customer’s installation and operating conditions. Provide the available space, load direction and interface drawing; the final mounting type and dimensions are defined in the approved project drawing.
Can the listed 1,000 kN overload be used continuously?
It should not be treated as a continuous working rating. The source distinguishes 400 kN axial thrust from instantaneous overload and static load; confirm permissible duration and operating conditions before selection.
Is the motor brake always supplied?
The source identifies the brake as an option. Specify the holding and stopping requirements and confirm the selected motor, drive and brake configuration in the quotation.